- The refurbished GE LightSpeed VCT and GE Lightspeed VCT XT 64-slice CT scanners are whole-body scanners designed for advanced cardiac and neuro imaging. The Lightspeed VCT XT is the higher-end model of the VCT, with the key differences being a 0.35 second rotation time and “Volume Shuttle” as a standard feature.
- Lightspeed qxi/plus/16 The GE LightSpeed is a third generation multi-slice helical CT scanner featuring a 53 kW generator, 6.3 MHU tube and a fast gantry rotation time of 0.5 seconds. The LightSpeed 16 is capable of imaging 16 slices per rotation with main collimators of 16 x 0.63 mm and 16 x 1.25 mm.
- GE Healthcare - LightSpeed VCT5-Beat Cardiac, covers 137.5 mm per second., The LightSpeed VCT can capture images of a beating heart in five heartbeats or an org.
- The GE LightSpeed VCT XT brings exceptional CT imaging power to the Discovery PET/CT 690. Combining volume coverage, superior resolution and reduced dose, the. The 64-slice LightSpeed VCT XT helps patient breath-holds to streamline studies. Remarkable reductions in dose.
- GE HEALTHCARE DIRECTION DOC1446909 REV 1 LIGHTSPEED VCT DICOM CONFORMANCE STATEMENT 4 of 188 REVISON HISTORY REV. VER DATE REASON FOR CHANGE 1 1 24 SEP 2013 Initial Draft Used DOC1290182 Rev.1 as a base. 1 2 2 OCT 2013 HII Log from Version 1.
GE HEALTHCARE DIRECTION DOC0860282, REV 3 BRIGHTSPEED AND LIGHTSPEED DICOM CONFORMANCE STATEMENT 4 of 172 REVISON HISTORY REV. DATE REASON FOR CHANGE 1 2 3 7/26/2011 New document number and product/sw version based on DOC0793025 Rev1.
GE Lightspeed VCT no load software
July 16, 2014 04:20
When you turn the computer starts the operating system without problems, but when running 'startup' I get a window with the following message:
[cupMonitor] GEOCommServer: created listen channel: inet_stream 192.9.101.30 51947|@tm
[cupMonitor] CupMonitorService : com.ge.med.fct.coreplatform.startup.CupMonitorEvent has been advertised by 1;serv=inet_stream 192.9.101.30 51947|@tm
chmod: changing permissions of `/tmp/.genameservice/': Operation not permitted
chmod: changing permissions of `/tmp/.genameservice/GEOCOMM': Operation not permitted
chmod: changing permissions of `/tmp/.genameservice/GEOCOMM/cupMonitor': Operation not permitted
----------------------------------------------
I need to know why this happens.
[cupMonitor] GEOCommServer: created listen channel: inet_stream 192.9.101.30 51947|@tm
[cupMonitor] CupMonitorService : com.ge.med.fct.coreplatform.startup.CupMonitorEvent has been advertised by 1;serv=inet_stream 192.9.101.30 51947|@tm
chmod: changing permissions of `/tmp/.genameservice/': Operation not permitted
chmod: changing permissions of `/tmp/.genameservice/GEOCOMM': Operation not permitted
chmod: changing permissions of `/tmp/.genameservice/GEOCOMM/cupMonitor': Operation not permitted
----------------------------------------------
I need to know why this happens.
re: GE Lightspeed VCT no load software
July 17, 2014 01:24
Have you try LFC
re: GE Lightspeed VCT no load software
July 17, 2014 01:25
Hi
The erro message is :
----------------------------------------------
CUP ERROR in ../../source/cupMakeCore.c line 200 pid 528
generating traceback file traceback.cupMonitor.201416Jul.120517
----------------------------------------------
The erro message is :
----------------------------------------------
CUP ERROR in ../../source/cupMakeCore.c line 200 pid 528
generating traceback file traceback.cupMonitor.201416Jul.120517
----------------------------------------------
re: re: GE Lightspeed VCT no load software
July 17, 2014 08:40
That could mean anything, your clue is that it fails at start up, if you don't want to do a LFC try a restoring system state first
re: re: re: GE Lightspeed VCT no load software
July 17, 2014 05:58
what is LFC?
re: re: re: re: GE Lightspeed VCT no load software
July 17, 2014 09:19
Load from cold , reload software on the computers
re: re: re: re: GE Lightspeed VCT no load software
July 17, 2014 09:19
Load from cold, reload software in the computers
re: re: re: GE Lightspeed VCT no load software
July 17, 2014 05:59
the gesys_vct_cdd.log show this error:
SR 204
1405339783 0 1 Mon Jul 14 12:09:43 2014 0 7
vct_cdd Svc_Notepad
Notepad.c 44
This message was added by the OPERATOR to report on a problem:
startMon failed to mount oc:/usr/g on DARC
EN 204
SR 389
1405341058 0 1 Mon Jul 14 12:30:58 2014 0 7
vct_cdd Svc_Notepad
Notepad.c 44
This message was added by the OPERATOR to report on a problem:
PRODUCT CONFIGURATION|Product: LightSpeed VCT|sw_version: 12HW14.6|sw_hw_string: 12HW14.6_SP1-1-1.V40_H_H64_G_GTL|host_id: 46211168|tube_type: 16|gantry_type: GANTRY_VCT_40|No. of processors: 4|Processor speed: 3200|memory: 4096
EN 389
SR 204
1405339783 0 1 Mon Jul 14 12:09:43 2014 0 7
vct_cdd Svc_Notepad
Notepad.c 44
This message was added by the OPERATOR to report on a problem:
startMon failed to mount oc:/usr/g on DARC
EN 204
SR 389
1405341058 0 1 Mon Jul 14 12:30:58 2014 0 7
vct_cdd Svc_Notepad
Notepad.c 44
This message was added by the OPERATOR to report on a problem:
PRODUCT CONFIGURATION|Product: LightSpeed VCT|sw_version: 12HW14.6|sw_hw_string: 12HW14.6_SP1-1-1.V40_H_H64_G_GTL|host_id: 46211168|tube_type: 16|gantry_type: GANTRY_VCT_40|No. of processors: 4|Processor speed: 3200|memory: 4096
EN 389
re: re: re: re: GE Lightspeed VCT no load software
July 18, 2014 10:04
It seems that your DARC is not working properly.
Try this Linux commands to see if you can communicate with it :
- ping darc
- rsh darc
If these commands are OK, your issue can be a bad DARC disk drive
Log inor RegisterTry this Linux commands to see if you can communicate with it :
- ping darc
- rsh darc
If these commands are OK, your issue can be a bad DARC disk drive
to rate and post a comment
re: re: re: GE Lightspeed VCT no load software
March 01, 2016 09:27
Ge Vct Lightspeed User Manual
hi! i have trouble with light speed 8 slice with Goc 4 console.
i need reload the software do you know how to do?
i put the DVD disc on the cpu i start the console and it put in boot mode and gave me some options to choice, one of them is recovery system , i can do this?
the problema is i have to replace the darc, but it not had the software installed.
Log inor Registeri need reload the software do you know how to do?
i put the DVD disc on the cpu i start the console and it put in boot mode and gave me some options to choice, one of them is recovery system , i can do this?
the problema is i have to replace the darc, but it not had the software installed.
to rate and post a comment
re: re: re: re: GE Lightspeed VCT no load software
March 02, 2016 09:12
Hi Miguel you need to load only the software for your darc, no LFC if you only Replace the darc.
[email protected] I am in México.
[email protected] I am in México.
re: re: re: re: GE Lightspeed VCT no load software
March 02, 2016 09:24
LFC should solve all your problems. Yes, load all the 3 disks and then the fourth is the applications disk. Do you know the passwords? I could send them to you if you need them. #bigbuy & 4$apps
re: GE Lightspeed VCT no load software
July 17, 2014 05:58
Dear
What is version of your console: GOC5, 5.5 or 6?
First: You check Ethernet card
Second: reconfig it
Third: LFW it
If three step above is not solved your problem, you can do LFC
Good Luck
Log inor RegisterWhat is version of your console: GOC5, 5.5 or 6?
First: You check Ethernet card
Second: reconfig it
Third: LFW it
If three step above is not solved your problem, you can do LFC
Good Luck
to rate and post a comment
re: re: GE Lightspeed VCT no load software
July 18, 2014 10:03
Hello, I agree with Tuy Do Duy,
If you need to know the version of your console, open a unix shell and type :
grep CONSOLETYPE /usr/g/config/INFO
If you have a GOC 5 or GOC 5.5, check if the host communicates with the DARC (use the following command : ping DARC) or look if the DARC has booted.
Good luck
If you need to know the version of your console, open a unix shell and type :
grep CONSOLETYPE /usr/g/config/INFO
If you have a GOC 5 or GOC 5.5, check if the host communicates with the DARC (use the following command : ping DARC) or look if the DARC has booted.
Good luck